3.5 Scaling in heat exchanger

Article Contents

Scaling in heat exchanger

Scaling in heat exchanger is one of the major problems in all types of heat exchanger.

Scaling

In industry we use different types of heat exchange to cool, heat, evaporation (reboiler), drying and condensation. There is different equipment use to do above job. Most common used heat exchanging equipment is, shell and tube heat exchange or boiler or chiller or plat type heat exchanger (PHE). So to maintain the performance of heat transferring equipment, it is necessary to avoid the scaling.

Scaling is noting but some accumulation or scale up of some inorganic salts inside the tube or inside the HE.

Scaling In Heat Exchanger

Definition of scaling? 

Scaling is process in which some chemical (mainly inorganic salts), accumulated inside the heat exchanger, which reduces the performance of HE.

Scaling in heat exchanger Animation

Two examples of scaling in heat exchanger?

First example is increase in hardness of water in boiler or boiler coil chock and second example of scaling is scaling in type of condenser.

Types of scaling in heat exchanger 

There are different types of scaling occur in heat exchanger.

how to prevent scaling in heat exchanger

As we know that scaling is nothing formation of scale. So, to avoid the scaling in the heat exchanger there are several ways,

  1. Use high velocity  
  2. Use soft water
  3. Always give blow down

Causes of scaling in heat exchanger  

The main reason behind the scaling is formation of salt or accumulation of particle or salt inside the tube of heat transfer equipment.  

What scaling

How to remove the scaling?

We can remove the scaling by any of the following method.

  1. To remove the scaling there are lot of chemicals available.
  2. Use high pressure water to remove the scale.
  3. Use high pressure steam or low-pressure steam to remove the scale in heat exchanger.
  4.  Use hot water. (But this may be applicable for special case where scale is dissolved in water)
  5. Give acid wash for several times.

What are the two methods of chemical cleaning?

script async src="https://pagead2.googlesyndication.com/pagead/js/adsbygoogle.js">

Generally used two methods for cleaning are,

  1. Acid cleaning
  2. Detergents.
  3. By air (very rare used)

scaling effect on heat exchanger

Scaling effect on heat exchanger is one of the main topics which we need to know.

The main effect of scaling on heat exchange are, scaling reduces the heat transfer coefficient (both overall and individual HTA), delta p across the heat exchanger may increase, it also reduces the heat exchanger performance.

What re the main two effect of scaling on heat exchanger?

The two main effects are scaling reduces the heat transfer coefficient and second is it increase differential pressure across the heat exchanger.

How do you prevent scaling in a heat exchanger?

how to prevent scaling in heat exchanger.

Use high velocity and use of soft water is best way to prevent the scaling.

Two why to prevent scaling in a heat exchanger?

Give blow down and use soft water.

The two Methods commonly used to remove scale on the surface of heat exchanger tube?

What is Fouling and scaling in heat exchanger?  

Fouling is formation of scale in heat exchanger or pipe due to any unwanted particles or chemical , scaling is scale in heat exchanger due to inorganic salts.

Keywords are,

Scaling in heat exchanger,  

types of scaling in heat exchanger,

how to prevent scaling in heat exchanger,

Difference between scaling and fouling in heat exchanger,

Read Also,

  how to prevent scaling in heat exchanger

fouling and scaling in heat exchanger

what is fouling in a heat exchanger?

scaling and fouling difference

difference between scaling and fouling in heat exchanger

causes of fouling in heat exchanger

fouling in heat exchanger pdf

what is fouling factor in heat exchanger

Acid cleaning of heat exchangers  

How do you remove calcium from a heat exchanger?

What are the 2 methods of chemical cleaning?

What is scaling in a heat exchanger?

Scaling in a heat exchanger refers to the accumulation of mineral deposits or scale on the inner surfaces of the exchanger, reducing its efficiency and heat transfer capabilities.

How does scaling occur in a heat exchanger?

Scaling occurs when the water or fluid being heated contains dissolved minerals, such as calcium and magnesium. As the fluid is heated and evaporates, these minerals precipitate and form solid deposits on the heat exchanger surfaces.

What problems can scaling cause in a heat exchanger?

Scaling can lead to decreased heat transfer efficiency, increased energy consumption, reduced flow rates, and even equipment failure due to blockage or corrosion.

How can scaling be prevented in a heat exchanger?

Scaling prevention can be achieved through various methods, including water treatment with chemical additives to inhibit scale formation, water softening techniques, regular cleaning and maintenance, and using materials with scale-resistant surfaces.

What are the consequences of ignoring scaling in a heat exchanger?

Ignoring scaling can result in a significant decline in heat exchanger performance, higher operational costs, frequent breakdowns, and the need for costly repairs or replacements.

How can scaling be detected in a heat exchanger?

Scaling can be detected through visual inspection, monitoring of pressure differentials, flow rate measurements, temperature differentials, or by conducting periodic water analysis to check for mineral content and scale-forming tendencies.

What are some common descaling methods for heat exchangers?

Descaling methods include chemical cleaning using acidic or alkaline solutions, mechanical cleaning using brushes or high-pressure water jets, and ultrasonic cleaning that utilizes high-frequency sound waves to remove scale deposits.

Can scaling be removed without dismantling the heat exchanger?

Yes, in many cases, scaling can be removed without dismantling the heat exchanger by using appropriate descaling methods, such as chemical cleaning or high-pressure water jetting.

How often should a heat exchanger be cleaned to prevent scaling?

The cleaning frequency depends on various factors such as the quality of the fluid being processed, the heat exchanger design, and operating conditions. Generally, regular inspections and cleaning schedules are recommended, ranging from monthly to annual intervals.

What are some long-term strategies to minimize scaling in heat exchangers?

Long-term strategies include implementing effective water treatment processes, optimizing fluid velocity and turbulence inside the exchanger, using materials with scale-resistant properties, and maintaining a regular cleaning and maintenance schedule.

how to prevent scaling in heat exchanger
types of scaling in heat exchanger
difference between scaling and fouling in heat exchanger
what is fouling in heat exchanger
fouling in heat exchanger pdf
difference between scaling and fouling in ro
fouling and scaling in heat exchanger
fouling effect on heat exchanger